    Partial fixity in steel single plate connections to HSS tube columns / Chad J. Whittinghill.
    by Whittinghill, Chad J.
    Subjects
  • Steel, Structural -- Specifications
  •  
  • Girders -- Joints
  •  
  • Strength of materials
  •  
  • Strains and stresses
  •  
  • MSST Project.
  • Description: 
    126 leaves : ill. ; 29 cm.
    Contents: 
    Thesis advisor: Christopher Raebel
    Committee members: Dr. Richard DeVries, Dr. Douglas Stahl
    Introduction -- Background -- Literature review -- Testing setup and procedure -- Results -- Conclusions -- A: Test data -- B: Additional photos -- C: Steel shop drawings -- D: Sample problem #1 -- E: Sample problem #2.
    When analyzing a structure, beam to column connections are classified as simple, fully restrained, or partially restrained. The type of end connection used in the analysis greatly affects the design of the beam and the column. Previous research has suggested that single shear plate connections, which are commonly designed as simple connections, may be stiffer than originally assumed. The scope of the previous research was limited to examine the accuracy of modeling single plate connections of beams to HSS tube columns as simple connections. The results of this research are used to demonstrate how modeling single plate connections as partially restrained, rather than simple, can lead to a more accurate analysis and possible cost savings.
    Connections were made between a W24x76 beam and HSS tube columns of varying size and thickness. A horizontal force and beam deflection were measured simultaneously throughout a predetermined load cycle. Each tube column section was tested using three separate bolt configurations. From this data, a rotational stiffness was determined for each trial connection. The rotational stiffness values were then used in sample problems to compare true moment and deflection behavior with the assumed behavior.
    The test connections all displayed moment-rotation behaviors that were well within the AISC recommendations for designing as simple shear connections. However, each connection was able to transfer moment to the column. While this moment transfer may be insignificant in many designs, understanding the true connection behavior may be valuable for beams with minor end moment demands.
    Add to my list 
    Copy/Holding information
    LocationCollectionCall No.Status 
    Walter Schroeder LibraryMaster's ThesesAC805 .W48 2009AvailableAdd Copy to MyList

    Format:HTMLPlain textDelimited