Item Information
Holdings
More by this author
Whittinghill, Chad J.
Subjects
Steel, Structural -- Specifications
Girders -- Joints
Strength of materials
Strains and stresses
MSST Project.
Browse Catalog
by author:
Whittinghill, Chad J.
by title:
Partial fixity in st...
MARC Display
Partial fixity in steel single plate connections to HSS tube columns / Chad J. Whittinghill.
by
Whittinghill, Chad J.
Subjects
Steel, Structural -- Specifications
Girders -- Joints
Strength of materials
Strains and stresses
MSST Project.
Description:
126 leaves : ill. ; 29 cm.
Contents:
Thesis advisor: Christopher Raebel
Committee members: Dr. Richard DeVries, Dr. Douglas Stahl
Introduction -- Background -- Literature review -- Testing setup and procedure -- Results -- Conclusions -- A: Test data -- B: Additional photos -- C: Steel shop drawings -- D: Sample problem #1 -- E: Sample problem #2.
When analyzing a structure, beam to column connections are classified as simple, fully restrained, or partially restrained. The type of end connection used in the analysis greatly affects the design of the beam and the column. Previous research has suggested that single shear plate connections, which are commonly designed as simple connections, may be stiffer than originally assumed. The scope of the previous research was limited to examine the accuracy of modeling single plate connections of beams to HSS tube columns as simple connections. The results of this research are used to demonstrate how modeling single plate connections as partially restrained, rather than simple, can lead to a more accurate analysis and possible cost savings.
Connections were made between a W24x76 beam and HSS tube columns of varying size and thickness. A horizontal force and beam deflection were measured simultaneously throughout a predetermined load cycle. Each tube column section was tested using three separate bolt configurations. From this data, a rotational stiffness was determined for each trial connection. The rotational stiffness values were then used in sample problems to compare true moment and deflection behavior with the assumed behavior.
The test connections all displayed moment-rotation behaviors that were well within the AISC recommendations for designing as simple shear connections. However, each connection was able to transfer moment to the column. While this moment transfer may be insignificant in many designs, understanding the true connection behavior may be valuable for beams with minor end moment demands.
Copy/Holding information
Location
Collection
Call No.
Status
Walter Schroeder Library
Master's Theses
AC805 .W48 2009
Available
Add Copy to MyList
Format:
HTML
Plain text
Delimited
Subject:
Email to:
Horizon Information Portal 3.25_9885
© 2001-2013
SirsiDynix
All rights reserved.